Wall socket 110 – 130 VAC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 110 - 130 VAC
Current: max. 16 A.
Poles : 1P + N + PE
Clock hour: 4
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
Cable entry: 2 x M25
View product

Flange socket 110 – 130 VAC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 110 - 130 VAC
Current: max. 16 A.
Poles : 1P + PE
Clock hour: 4
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
View product

Coupler 110..130 VAC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 110..130 VAC
Current: max. 16 A.
Poles : 1P +N+PE
Clock hour: 4
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
Cable entry: 8 to 20 mm.
View product

Plug 110 – 130 VAC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 110 - 130 VAC
Current: max. 16 A.
Poles : 1P + N + PE
Clock hour: 4
to turn on by rotate plug
Material: glas fibre reinforced polyester
Cable entree: 8 to 20 mm.
Degree of protection after connection: IP66
Note: protection cover order seperate
View product

Wall socket 200 – 250 VAC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 200 - 250 VAC
Current: max. 16 A.
Poles : 1P + N + PE
Clock hour: 6
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
Cable entry: 2 x M25
View product

Flange socket 200 – 250 VAC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 200 - 250 VAC
Current: max. 16 A.
Poles : 1P + N + PE
Clock hour: 6
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
View product

Coupler 200 – 250/3P
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 200 - 250 VAC
Current: max. 16 A.
Poles : 1P + N + PE
Clock hour: 6
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
Cable entry: 8 to 20 mm.
View product

Plug 200 – 250 VAC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 200 - 250 VAC
Current: max. 16 A.
Poles : 1P + N + PE
Clock hour: 6
to turn on by rotate plug
Material: glas fibre reinforced polyester
Cable entry: 8 to 20 mm.
Degree of protection after connection: IP66
Note: protection cover can be ordered seperately
View product

Wall socket 20 – 24 V AC/DC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 20 - 24 V AC/DC
Current: max. 16 A.
Poles : 2P
Clock hour: 12
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
Cable entry: 2 x M25
View product

Flange socket 20 – 25 V AC/DC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 20 - 25 V AC/DC
Current: max. 16 A.
Poles : 2P
Clock hour: 12
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
View product

Coupler 20..25 C AC/DC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 20 .. 24 V AC/DC
Current: max. 16 A.
Poles : 2P
Clock hour: 12
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
Cable entry: 8 to 20 mm.
View product

Plug 20 – 25 V AC/DC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 15 - 25 V AC/DC
Current: max. 16 A.
Poles : 2P
Clock hour: 12
to turn on by rotate plug
Material: glas fibre reinforced polyester
Cable entry: 8 to 20 mm.
Degree of protection after connection: IP66
Note: protection cover can be ordered seperately
View product

Wall socket 42 – 50 V AC/DC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 42 - 50 V AC/DC
Current: max. 16 A.
Poles : 2P
Clock hour: 12
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
Cable entry: 2 x M25
View product

Flange socket 42 – 50 V AC/DC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 42 - 50 V AC/DC
Current: max. 16 A.
Poles : 2P
Clock hour: 12
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
View product

Coupler 40..50 C AC/DC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 40 .. 50 V AC/DC
Current: max. 16 A.
Poles : 2P
Clock hour: 12
to turn on by rotate plug
Material: glas fibre reinforced polyester
Degree of protection: IP66
Cable entry: 8 to 20 mm.
View product

Plug 42 – 50 V AC/DC
Ex Mark:
II 2 G - Ex de IIC T6
II 2 D - Ex DIP A21 Ta 80 C
Voltage: 42 - 50 V AC/DC
Current: max. 16 A.
Poles : 2P
Clock hour: 12
to turn on by rotate plug
Material: glas fibre reinforced polyester
Cable entry: 8 to 20 mm.
Degree of protection after connection: IP66
Note: protection cover can be ordered seperately
View product

Protection cover for 3 pole plug
to be used in combination with plug types:
- Z0251 - 24V - 42024
- Z0251 - 42V - 42050
- Z0251 - 115V - 43115
- Z0251 - 230V - 43230
View product